en:ost:telescope:c11_bedienung

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
en:ost:telescope:c11_bedienung [2017/10/20 21:26] – [Setup] rhainichen:ost:telescope:c11_bedienung [2024/02/20 09:07] (current) rhainich
Line 1: Line 1:
-/* +====== CGE PRO ======
-<WRAP center round important 40%> +
-**Work in progress!** +
-</WRAP> +
-*/ +
-FIXME **This page is not fully translated, yet. Please help completing the translation.**\\ //(remove this paragraph once the translation is finished)//+
  
-====== C11 & CGE PRO ======+<WRAP group> 
 +<WRAP half column> 
 +Celestron'CGE PRO is a rugged, computer-controlled German equatorial mount suitable for both astrophotography and visual observation. With a generous payload capacity of up to 41kg, it can effectively accommodate large telescopes and heavy imaging equipment. The precision gears and motors allow for accurate tracking and alignment, although our model is getting older and no longer achieves such high precision. With autoguiding support, however, this is not noticeable.  
 +In addition, features such as the All-Star Polar Alignment and accessories such as the NexStar+ hand control and StarSense AutoAlign module allow the mount to be set up and aligned efficiently. 
  
-The C11 is our second largest telescope and suitable for mobile use. Every time one likes to use it, one has to put it up again from scratch. The purpose of this article is to describe the details of this process. +===== Individual parts =====
- +
-===== Scattered pieces ===== +
- +
-To protect the sensitive electronics from humidity and other harsh weather conditions they are stored in the lab course room. The remaining mechanical parts stay in the dome, so that one does not need to carry them around.+
  
 +To protect the sensitive electronics from humidity and other harsh weather conditions they are stored in the lab course room. 
 === Stored in the dome: === === Stored in the dome: ===
  
-  - the tripod +  - the tubes (C11, RASA)
-  - the tube (C11)+
   - counterweights + bar   - counterweights + bar
  
 === Stored in lab course room: === === Stored in lab course room: ===
  
 +  - the tripop
   - the CGE PROs electronic box   - the CGE PROs electronic box
   - the CGE PRO mount   - the CGE PRO mount
   - a box containing all 1.4″ eyepieces and the corresponding filters   - a box containing all 1.4″ eyepieces and the corresponding filters
   - sun filters   - sun filters
 +
 +</WRAP>
 +<WRAP half column>
 +[{{ost:c11:cge-pro_c11.jpg | CGE PRO mit C11}}]
 +</WRAP>
 +</WRAP>
  
 ===== Setup ===== ===== Setup =====
  
-  - The CGE PRO uses a parallactic mount, which has to be adjusted to point to the northern celestial pole. Therefore, the tripod (see <imgref stativ>) should be positioned accordingly. To do so, it is usually sufficient to point the tripod leg with the carrier for the hand terminal to the south.+  - The CGE PRO is a parallactic mount, which has to be adjusted to point to the northern celestial pole. Therefore, the tripod (see <imgref stativ>) should be positioned accordingly. To do so, it is usually sufficient to point the tripod leg with the carrier for the hand terminal to the south.
   - Now put the electronic box on the tripod (see <imgref ebox>) and fix it with three bolts (see <imgref screwsebox>).     - Now put the electronic box on the tripod (see <imgref ebox>) and fix it with three bolts (see <imgref screwsebox>).  
-  - For the next step place the mechanics of the CGE PRO mount (see <imgref cgepro>) on the electronic box and again fix it with three bolts (see <imgref cgepro+ebox>). Due to the heavy weight of the mechanics, this step should be performed by two people.+  - Place the mechanics of the CGE PRO (see <imgref cgepro>) on the electronic box and fix it again with three bolts (see <imgref cgepro+ebox>). Due to the heavy weight of the mechanics, this step should be performed by two people.
   - Screw the counterweight bar into the mechanics and place the counterweights on it (see <imgref counterweight>). When you fasten the screws on them, they are hold in place.    - Screw the counterweight bar into the mechanics and place the counterweights on it (see <imgref counterweight>). When you fasten the screws on them, they are hold in place. 
   - Connect the electronic box to the engines of the mount. The cables (see <imgref cables>) go in the ports on the side of the electronic box (<imgref ebox+connections>). The cables have different lengths. The short one connects electronic box with the right-ascension axis, while the longer one is for the declination axis (see <imgref connected>). The cables only fit in one position.   - Connect the electronic box to the engines of the mount. The cables (see <imgref cables>) go in the ports on the side of the electronic box (<imgref ebox+connections>). The cables have different lengths. The short one connects electronic box with the right-ascension axis, while the longer one is for the declination axis (see <imgref connected>). The cables only fit in one position.
Line 121: Line 122:
 ===== Start-up ===== ===== Start-up =====
  
-The CGE PRO can simply switched on and off via the ''On/Off'' switch at the electronic box. In contrast to the OST, the CGE PRO does not require any shutdown procedure. It simply can be switched off. After the boot of the mount, it is almost always required to perform an alignment. The following possibilities exist:+The CGE PRO can simply switched on and off via the ''On/Off'' switch at the electronic box. In contrast to the OST, the CGE PRO does not require any shutdown procedure. It simply can be switched off. After the boot of the mount, it is almost always required to create a new alignment. The following possibilities exist:
  
   * Two Star Align   * Two Star Align
Line 130: Line 131:
   * Re-Alignment   * Re-Alignment
  
-Unfortunately, the handling of the hand terminal of the CGE PRO is not as intuitive as the one of the OST. However, after a short settling in period also an inexperienced user can safely handle this mount.  +Unfortunately, the handling of the hand terminal of the CGE PRO is not as intuitive as the one of the OST. However, after a short settling in period even an inexperienced user can safely handle this mount.  
 ===== Alignment ===== ===== Alignment =====
  
-Usually it is required to create a new alignment after each setup of the mount. If one wants to use more than one night in a row, there is the opportunity to put the mount into a hibernation mode (see below) that allow to disconnect the mount from the power supply and at the same time to conserve the alignment. If the mount is used at a fixed position, one also can make use of a saved alignment. +Usually it is required to create a new alignment after each start of the mount. If we want to use the telescope more than one night in a row, we have the opportunity to put the mount into a hibernation mode (see below) that allows to disconnect the mount from the power supply and at the same time to conserve the alignment. If the mount is used at a fixed position, one also can use  previously saved alignment. 
  
 General procedure: General procedure:
Line 149: Line 150:
 ==== Solar System Alignment ==== ==== Solar System Alignment ====
  
-The Solar System Alignment is useful especially for solar observations, since one can use directly to perform the alignment. While the precision of the Solar System Alignment is lower than what one can achieve with an alignment procedure that is based on several stars, it is usually sufficient for our purposes. Before the the can be used as an alignment star, it is required to allow the telescope to actually move to the sun, since this in blocked by default for security reasons. this can be done via //UTILITIES// -> //SUN MENU// -> //ENTER//. Apart from the points mentioned above, the Solar System Alignment requires the following steps:+The Solar System Alignment is useful especially for solar observations, since one can directly use the Sun to create the alignment. While the precision of the Solar System Alignment is lower than what one can achieve with an alignment procedure that is based on several stars, it is usually sufficient for solar observations. Before the Sun can be used as an alignment star, it is required to allow the telescope to actually move to the Sun because this in blocked by default for security reasons. This can be done via //UTILITIES// -> //SUN MENU// -> //ENTER//. Apart from the points mentioned above, the Solar System Alignment requires the following steps:
  
   - select //Solar System Align// (with the ↑ and ↓ buttons and **not** with the NSWO buttons)    - select //Solar System Align// (with the ↑ and ↓ buttons and **not** with the NSWO buttons) 
Line 161: Line 162:
 The Two-Star Alignment and it refinement with additional stars is the default procedure to build a new alignment for night observations. Besides the points mentioned above the following steps are necessary: The Two-Star Alignment and it refinement with additional stars is the default procedure to build a new alignment for night observations. Besides the points mentioned above the following steps are necessary:
  
-  - select //Two Star Align// from the menu -> subsequently, the telescope suggests bright stars, which are above the horizon+  - select //Two Star Align// from the menu -> subsequently, the telescope suggests bright stars that are above the horizon
   - select and confirm the first calibration star with //ENTER//    - select and confirm the first calibration star with //ENTER// 
   - center the star in the eyepiece (the finderscope is often not very helpful, since it is most of the time not well aligned with tube)   - center the star in the eyepiece (the finderscope is often not very helpful, since it is most of the time not well aligned with tube)
   - confirm with //ENTER//   - confirm with //ENTER//
   - press //ALIGN// -> afterwards the telescope suggests the second alignment star   - press //ALIGN// -> afterwards the telescope suggests the second alignment star
-  - center also this star in the eyepiece (in case it is not possible to find the star, one can select a new stat by pressing //UNDO//)+  - select and confirm the second calibration star with //ENTER//  
 +  - center also this star in the eyepiece (in case it is not possible to find this star, one can select a new star by pressing //UNDO//)
   - confirm with //ENTER//   - confirm with //ENTER//
   - press //ALIGN// -> subsequently, the alignment can be improved with additional stars (3 are recommended, 6 are possible)    - press //ALIGN// -> subsequently, the alignment can be improved with additional stars (3 are recommended, 6 are possible) 
-  - press //UNDO// to complement alignment+  - press //UNDO// to complete the alignment
  
 ===== Hibernation ===== ===== Hibernation =====
  
-The hibernation modus offers the possibility to use the telescope several nights in a row, while switching off the power supply during the day. The hibernation procedure ensures that the alignment will be conserved. However during hibernation, it is not allowed to move the telescope at all. The following steps are necessary to put the telescope into hibernation:+The hibernation mode offers the possibility to use the telescope several nights in a row, while switching off the power supply during the day. It ensures that the alignment will be conserved. However during hibernation, it is not allowed to move the telescope at all. The following steps are necessary to put the telescope into hibernation:
  
   - press the //MENU// button   - press the //MENU// button
Line 195: Line 197:
 ===== Additional documentation ===== ===== Additional documentation =====
  
-More details on the CGE PRO and the C11 can be found in the corresponding manuals in the lab course room.+More details on the CGE PRO can be found in the corresponding manuals in the lab course room.
  • en/ost/telescope/c11_bedienung.1508534766.txt.gz
  • Last modified: 2017/10/20 21:26
  • by rhainich