Line 20: Line 20:
 ^ 10    | Before using the telescope you have to tare the rotation axes. First lose the clutch knobs fixing the right-ascension axis, until you can freely move the telescope around this axis. Now adjust the position of the counterweight such that there is no movement along this axis anymore. Tighten the clutch knobs again and repeat this procedure for the declination axis. As there are no counterweights for this axis, one has to shift the tube along the clamp to tare the declination axis.    |   {{ost:c8:IMG_7108_small.jpg?300}}  | {{ost:c8:011_resize.jpg?300}}  | ^ 10    | Before using the telescope you have to tare the rotation axes. First lose the clutch knobs fixing the right-ascension axis, until you can freely move the telescope around this axis. Now adjust the position of the counterweight such that there is no movement along this axis anymore. Tighten the clutch knobs again and repeat this procedure for the declination axis. As there are no counterweights for this axis, one has to shift the tube along the clamp to tare the declination axis.    |   {{ost:c8:IMG_7108_small.jpg?300}}  | {{ost:c8:011_resize.jpg?300}}  |
 ^ 11    | Afterwards the axes need to be justified. To do this, they need to be move to the index positions as illustrated in the image.    {{ost:c8:IMG_7122_small.jpg?300}} {{ost:c8:IMG_7124_small.jpg?300}}  |  {{ost:c8:011_resize.jpg?300}}  | ^ 11    | Afterwards the axes need to be justified. To do this, they need to be move to the index positions as illustrated in the image.    {{ost:c8:IMG_7122_small.jpg?300}} {{ost:c8:IMG_7124_small.jpg?300}}  |  {{ost:c8:011_resize.jpg?300}}  |
-^ 12    | Now the alignment can be performed. This procedure is very similar to the one of our  [[en:ost:telescope:c11_bedienung#alignment|C11]] with the exception that the mount will not automatically move to the index positions but fortunately you already did this in the step before.  |    |  {{ost:c8:011_resize.jpg?300}}  |+^ 12    | Now the alignment can be performed. This procedure is very similar to the one of our  [[en:ost:telescope:c11_bedienung#alignment|CGE-PRO]] with the exception that the mount will not automatically move to the index positions but fortunately you already did this in the step before.  |    |  {{ost:c8:011_resize.jpg?300}}  |
 ^ 13    | Finished!  |    | {{ ost:c8:build_c8.gif }}  | ^ 13    | Finished!  |    | {{ ost:c8:build_c8.gif }}  |
      
Line 26: Line 26:
 ===== Functions such as Hibernation ===== ===== Functions such as Hibernation =====
  
-The operation of the Advanced GT as well as features like hibernation do not differ from the CGE-Pro and can be found in the article on the [[en:ost:telescope:c11_bedienung#alignment|C11]].+The operation of the Advanced GT as well as features like hibernation do not differ from the [[en:ost:telescope:c11_bedienung#alignment|CGE-Pro]].
  
 ===== Troubleshooting ===== ===== Troubleshooting =====