====== Known problems, issues, and their solution ====== ===== GM4000 HPS II ===== ==== Loss of the alignment ==== **Description of the problem:** The current alignment has been lost, e.g. by an incorrect operation (delete Alignment). **Solution:** Restore a previously saved alignment. If such an alignment exists, it can be selected with: MENU - Alignment - Align Database - Load Model If there is no saved alignment, you will have to [[en:ost:telescope:setup|create a new alignment]]. ==== Problems with finding objects ==== **Description of the problem:** The telescope does not point to the selected objects or to wrong ones. **Solution:** Possible solutions are in this order: * check date and time (is DST set -- only during summer) and the location in the settings of the hand terminal * restore an old alignment (see above) * create a new alignment (see [[en:ost:telescope:setup#Alignment|here]]). ==== Problems with the tracking speed ==== **Description of the problem:** The tracking speed does not automatically adjust to the target, i.e. the moon. **Solution:** By default, the following option should be enabled: Menu - Drive - Follow Obj If it is not, the automatic switching between different tracking modes does not work. ==== Problems with the park position ==== **Description of the problem:** The telescopes does not move to the default park position (pointing to the northern celestial pole). **Solution:** The solution is to switch back to the default park position via: Menu - Alignment - Park Position - Default park ===== Dome: ===== ==== Dome wall vs. telescope I ==== **Description of the problem:** The dome's wall obscures the view of the telescope to the sky. This happens when the dome does not follow the pointing of the telescope, i.e. the open shutter is not in phase with the telescope. **Solution:** The dome control can determine the current position of the dome by means of a magnet. For this purpose, the dome must be moved through the south point once: - Disconnect the dome from the telescope. To do this, go to the **Dome tab** in //Maxim DL// in the **Observatory control window** and deactivate the option ''Dome Tracks Scope''. - Then the dome can be moved around using the dome remote control or in //Maxim DL// in the **Dome tab** of the **Observatory control window** using the options in the ''Postions'' section. For the latter, the desired target azimuth (''Azimuth'') must be selected and then ''Go To'' clicked. - Finally, re-establish the connection between the dome and the telescope. {{ ost:software:maximdl:maxim_dl_observatory_dome_marked.png| Dome tab in the Observatory control window }} ==== Dome wall vs. telescope II ==== **Description of the problem:** The motor that drives the dome rotation can be heard but the dome does not rotate. **Solution:** - Push in the red emergency switch on the control unit for the dome (see [[this>lib/exe/fetch.php?media=ost:telescope:control-box.jpg|here]]). - Disconnect the dome from the telescope. To do this, go to the **Dome tab** in //Maxim DL// in the **Observatory control window** and deactivate the option ''Dome Tracks Scope''. - Pull out the emergency switch again. The dome can now be operated again using the remote control. - Now press the azimuth buttons alternately until the dome moves freely again. - Finally, re-establish the connection between the dome and the telescope. {{ ost:software:maximdl:maxim_dl_observatory_dome_marked.png| Dome tab in the Observatory control window }} ==== Shutter vs. hatch I ==== **Description of the problem:** The shutter of the dome does not close completely and a small gap remains between the shutter and the hatch. **Solution:** Open the shutter until it is possible to move the hatch. Open the hatch a bit and close it again. Afterwards, it should be possible to completely close the shutter. ==== Shutter vs. hatch II ==== **Description of the problem:** The shutter or the hatch do not close via the remote control. **Solution 1:** On the hand terminal, use the command to close the dome completely: MENU - Settings - Dome - Close Shutter. After that, the hatch and shutter should open and close properly again using the remote control. **Solution 2:** In //Maxim DL// in the **Observatory control window** go to the **Dome-Tab** and try to open the dome again with ''Open''. Afterwards close it with ''Close''. {{ ost:software:maximdl:maxim_dl_observatory_dome_marked_2.png | Dome tab in the Observatory control window }} ==== Shutter and/or hatch do not move smoothly ==== **Problem description:** The Sshutter and/or hatch do not move smoothly when controlled by the remote control. **Solution:** This is normal when the dome is coupled to //Maxim DL// at the same time. In this case the signals coming from the remote control overlap with the signals coming from //Maxim DL//. If the dome is to be controlled manually, it is recommended to disconnect it from //Maxim DL//. However, if there is currently no connection to //Maxim DL//, there might be a serious problem. In this case, immediately contact the technical staff. ==== Shutter and/or hatch cannot be moved at all ==== **Problem description:** The shutter and/or hatch can no longer be moved even with the methods described above, because a component may have broken. **Solution:** - Switch off controls and power supply * Turn the **main switch** on the right side of the gray dome control box **to OFF** (Fig. 1) - Close the hatch * **Move the lever** (Fig. 2) on the top of the hatch hydraulics (located to the right of the dome slit) **to the left and in a horizontal position** * **Close the hatch** manually by pressing from the outside - Close the shutter * **Remove the black protective cover** above the slipping clutches (red circles in Fig. 3) of the shutter drives * **Take** the **Allen wrench** (green ellipse in Fig. 3) from its holder directly next to the left-hand slipping clutch * **Release the slipping clutches** of the shutter drives → to do this, **loosen the Allen screws** located in a circle (Fig. 4) * **Insert** the **emergency crank** (Fig. 5, located on the left side of the dome slit) **into the socket** to the right of it (blue ellipse in Fig. 3). * **Crank shutter** manually [{{ost:dome:dome_control_box.jpg| Fig. 1: Dome control box - red: main switch}}] [{{ost:dome:shutter_mechanism.jpg| Fig. 3: Shutter mechanism - red: slipping clutches, green: Allen wrench, blue: socket for the emergency crank handle}}] \\ [{{ost:dome:slipping_clutchmod.jpg| Fig. 4: Slipping clutch with Allen screws}}] [{{ost:dome:hatch_hydraulics_lever.jpg| Fig. 2: Hatch hydraulics - red: lever for switching it off}}] \\ [{{ost:dome:emergency_crank_handle.jpg| Fig. 5: Emergency crank handle}}] ===== Telescope: ===== ==== Focuser of the CDK20 does not run the complete range of ~35000μ ==== **Problem description:** PWI3 shows clearly negative position values when driving in or the focuser does not run in the positive range (when driving out) up to the maximum ~35000μ. **Solution:** The focuser has "swallowed" and the encoder delivers wrong values. This can be fixed by clicking on ''Home'' (see picture) in the Focuser tab of PWI3 under ''Find Home and Reset'' and then on ''YES''. This will reset the focuser and reinitialize the home position, restoring the normal focus range. {{ ost:software:pwi3_homing_focuser.png }} ==== Wobbling Camera/spectrograph ==== **Description of the problem:** You may find that the camera or spectrograph still wobble or rotate despite your efforts to secure them to the telescope. **Solution:** The screws for attaching devises could be rusty and therefore, it is hard to tighten them. Thus, the screws should be completely unscrewed. After checking them they should be cleaned or if they are too damage, they should be exchanged. In general it can't be bad to unscrew them from time to time to check them. In the worst case the screw thread is damaged and then it has to be cleaned or the thread needs a new cut. ===== C11/C14 and the CGE-Pro mount: ===== ==== No Response-Errors ==== **Description of the problem:** The hand terminal shows the error message //No Response 16// or //No Response 17//. **Solution:** These error codes appear in case the communication between control unit and engines of the right ascension axis and/or declination axis is disturbed. First, check if all cables are correctly plugged in. If that didn't solve the problem, use contact spray on the connectors of the plugs (attention: Do not directly spray into the sockets). If the problem persists, the hand terminal is probably broken. ==== Loose bolts at the electronic box of the CGE-Pro ==== **Description of the problem:** The sockets for the right ascension and the declination cable of the electronic box are loose and it is not possible to tighten them. **Solution:** The bolts that hold the sockets are countered from inside the box by means of nuts. Therefore, it is inevitable to open the box. The cover of the box is bolted into the upper part of it. Since the cover is plain with the exception of a few boreholes, it could be a bit troublesome to remove it. One can try to turn the cover by means of a screwdriver but one has to be very careful in order not to damage the electronics. However, the best option is to build a special tool for this purpose. In each case a certain amount of strain is necessary to open the electronic box. Therefore, it probably is a good idea to get some help, so that somebody or something can hold the box while turning the cover. When the box is open, the bolts of the sockets can be easily tightened. Subsequently, the electronic box can be closed again. It is important to carefully tighten the cover. Otherwise, it might be not possible to attach the mechanics to the electronic box when the mount is set up. ===== C9 and the advanced GT mount: ===== ==== Telescope pointing ==== **Description of the problem:** Instead of driving towards objects correctly and precise, the telescope points to the ground. Furthermore, the movements of the telescope (along larger distances) are (very) slow. **Solution:** It's likely that the power supply is causing the problem. Try a different power supply. ===== Cameras: ===== ==== Ice on the camera ==== **Description of the problem:** The CCD chip of the camera has experienced icing, see image on the right. **Solution:** The cameras' interior is not in a vacuum and moisture can get in, causing icing on the cooled CCD chip. To prevent this, the cameras have dry cartouches with desiccants. If icing appears, the cartouches need to be regenerated ([[en:ost:ccds:grunddaten#maintenance|see this article]]). During that observational night, wait for approximately one hour until the ice sublimates from the CCD chip. ==== ST-8: shutter error ==== **Description of the problem:** //CCDops// reports ''shutter error'' while taking the first images after switching on the camera. **Solution:** In this case the communication between the camera and //CCDops// is disturbed or the sensors for the shutter position do not work properly. Therefore, the software does not know whether the shutter is closed or not. It also could be that the shutter is indeed not moving as expected. In each case, it is often sufficient to switch off the camera and to disconnect it from the power supply. However, sometimes it is necessary to detach the camera from the telescope and to very carefully shake the camera a bit. Afterwards, the sensors of the shutter usually deliver proper data again. ==== Maxim DL: Two SBIG cameras cannot be simultaneously connected ==== **Description of the problem:** When trying to couple two SBIG cameras simultaneously with //Maxim DL//, //Maxim DL// becomes very slow, hangs or crashes. **Solution:** This can be due to the fact that ''Camera threading on (recommended)'' is set in the camera options. This option must be deactivated for the SBIG cameras. Afterwards the cameras should connect and work as usual. [{{ ost:ccds:m15_eis.jpeg | Exposure of the cluster M15 with the ST-8. The left side clearly shows icing on the CCD. }}] \\ \\ \\ [{{ ost:software:maximdl:options_menu_cameras_marked.png | Camera options menu in //Maxim DL// }}] ==== CCDops does not find the filter wheel ==== **Description of the problem:** //CCDops// does not find the filter wheel of the STF8300 camera although the filter wheel is rotating when the power is switched on. **Solution:** The filter wheel needs to be reinitialized. The corresponding menu can be found via ''Filter'' and ''Filter Setup''. Select the "FW-5" filter wheel from the drop down menu and confirm the settings with a click on the ''OK'' button. Afterwards the filter wheel should work again. ====== Manuals ====== Current user's manuals are in the laboratory course room (2.009): {{section>deng:ost:manuals#Englisch&noheader}} ====== Resolved problems that should no longer occur ====== ++++ GM 4000 Mount: Tracking error | The following image illustrates the telescope's tracking problem. On the left panels, you can see the globular cluster M 13. The lower left panel shows an exposure of 10s, which gives a fair result. The upper left panel combines 135 exposures of each 10s, so approx. 35 minutes in total. The stars are clearly smeared and describe a fine zig-zag line (length of about 1/2'). The right panels show the exposures of an open cluster of 30s exposure time. Again, the lower right panel shows one exposure, the upper right the combinations of all following exposures. Note: The exposures were taken with the ST-8 and are not fully reduced here. [{{:ost:telescope:tracking_error.png?900|Tracking errors of a globular cluster (M 13, left panels) and an open cluster (right panels)}}] [{{https://polaris.astro.physik.uni-potsdam.de/ftp/tracking_error/animation_20140515_5s.gif?550&nocache|300 exposures of NGC 6819 at intervals of 5 seconds, dated 15 May 2014}}] [{{https://polaris.astro.physik.uni-potsdam.de/ftp/tracking_error/animation_20140808_NGC6819_5s.gif?550&nocache|201 exposures of NGC 6819 at intervals of 5 seconds, dated 8 August 2014, after calibration of the [[en:ost:telescope:setup#a-PEC|Periodic Error Control]]}}] [{{https://polaris.astro.physik.uni-potsdam.de/ftp/tracking_error/animation_20140515_1s.gif?550&nocache|300 exposures of NGC 6819 at intervals of 1 second, dated 15 May 2014}}] [{{https://polaris.astro.physik.uni-potsdam.de/ftp/tracking_error/animation_20140808_NGC6819_1s.gif?550&nocache|805 exposures of NGC 6819 at intervals of 1 second, dated 8 August 2014, after calibration of the [[en:ost:telescope:setup#a-PEC|Periodic Error Control]]}}] ++++ ++++ GM 4000 Mount: The mount does not stop slewing | **Description of the problem:** Using the handheld terminal or //Maxim DL//, the mount moves to the target position, but does not start tracking and instead remains in the slewing phase. **Solution:** The problem seems to be due to an interaction between the handheld terminal and //Maxim DL//. The solution is to disconnect the telescope in //Maxim DL// and then reconnect it. It also helped to click on ''Abort'' in the **Telescope** tab in the **Observatory** control within //Maxim DL// and then slew to the object again. ++++ ++++ GM 4000 Mount: Noise similar to a ship horn | **Description of the problem:** The telescope makes a loud noise similar to a ship horn when it is moved around the right ascension axes. The noise can be so loud that it is noticeable in the whole building. So far the problem only occurred at temperatures close to the freezing point. **Solution:** The problem is a result of a too high pressure of the worm on the worm wheel. Therefore, this pressure needs to be reduced. A detail description how to do this can be found among the manuals in the lab-course office and in the svn. ++++